Mastervolt AC Master 12V Range

Mastervolt sine wave inverters have proven themselves under the most extreme conditions for over 25 years.

Enquire about this product

Nationwide Shipping & Support

Guaranteed Safe Checkout

MASTERVOLT-acmaster-12V-Range
Mastervolt AC Master 12V Range

    Call Back request

    Mastervolt AC Master 12V Range Mastervolt sine wave inverters have proven themselves under the most extreme conditions for over 25 years. Our inverter family consists of AC Master, Mass Sine and Mass Sine Ultra models, ranging from 300 watt up to 40 kW. The AC Master is ideal for small and medium-sized applications, while Mass Sine and the advanced Mass Sine Ultra inverters are mainly intended for larger systems and for professional purposes. Features
    • Pure sine wave technology protects sensitive equipment.
    • Delivers full output at high peak power under the most demanding conditions.
    • Automatic power saving system for extended runtime.
    • Compact and lightweight design, saving valuable installation time.
    • Reliable and safe operation; protected against over-temperature, overload, short circuit, high or low battery voltage.
    • Variable speed fan for quiet operation at low power.
    • Optional remote control for instant switch off of the inverter and all connected equipment (not available for the 300 and 500 W models).
    • Convenient plug connection for all models, 2500/3500 Watt models also hard wired.

    Mastervolt AC Master 12V Range Specifications


    AC Master 12V 300W

    Output voltage 230 V – 50 Hz (± 0.1%)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 60 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 300 W
    Continuous power at 40 °C / 104 °F, cos phi 1 250 W
    Peak load 600 W
    AC connection universal
    Efficiency 90 %
    Display/read-out LED display
    Alarms 4 alarm modes
    Dimensions, hxwxd 210 x 130 x 60 mm 8.3 x 5.1 x 2.4 inch
    Weight 1.16 kg 2.6 lb
    Approvals CE, E-mark, ABYC A-31

    AC Master 12V 1500W

    Output voltage 200/220/230/240 V – 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 130 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 1000 W
    Continuous power at 40 °C / 104 °F, cos phi 1 1000 W
    Peak load (1 min.) < 1150 W
    Peak load (1 sec.) < 1750 W
    AC connection plug connection EU (Schuko), with UK plug (code 28211000) or with NZ/AU plug (code 28411000)
    Efficiency 92 %
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 200 x 372 x 83 mm 7.9 x 14.6 x 3.3 inch
    Weight 3.3 kg 7.3 lb
    Approvals CE, E-mark, RCM

    AC Master 12V 700W (120V)

    Output voltage 100/110/115/120 V – 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 100 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 700 W
    Continuous power at 40 °C / 104 °F, cos phi 1 700 W
    Peak load (1 min.) < 810 W
    Peak load (1 sec.) < 1230 W
    AC connection North American socket with GFCI
    Efficiency 91 %
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 200 x 330 x 83 mm 7.9 x 13.0 x 3.3 inch
    Weight 2,6 kg 5.7 lb
    Approvals safety: UL 458, EMC: FCC class B

    AC Master 12V 500W

    Output voltage 230 V – 50 Hz (± 0.1%)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 100 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 500 W
    Continuous power at 40 °C / 104 °F, cos phi 1 400 W
    Peak load 800 W
    AC connection universal
    Efficiency 90 %
    Display/read-out LED display
    Alarms 4 alarm modes
    Dimensions, hxwxd 210 x 130 x 60 mm 8.3 x 5.1 x 2.4 inch
    Weight 1.22 kg 2.7 lb
    Approvals CE, E-mark, ABYC A-31

    AC Master 12V 2000W

    Output voltage 200/220/230/240 V 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 200 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 2000 W
    Continuous power at 40 °C / 104 °F, cos phi 1 2000 W
    Peak load (1 min.) < 2300 W
    Peak load (1 sec.) < 4000 W
    AC connection plug connection EU (Schuko)
    Efficiency 94 %
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 248 x 443 x 83 mm 9.8 x 17.4 x 3.3 inch
    Weight 5.2 kg 11.5 lb
    Approvals CE, Safety: EN60950-1, E-mark: CISPR25, ISO11452-2, ISO7637-2, EMC: EN55022, EN55024, EN61000- 3-2; -3-3, EN61000-4,2,3,4,5,6,8,11

    AC Master 12v 2000w (120v)

    Output voltage 100/110/115/120 V – 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 200 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 2000 W
    Continuous power at 40 °C / 104 °F, cos phi 1 2000 W
    Peak load (1 min.) < 2300 W
    Peak load (1 sec.) < 3500 W
    AC connection North American socket with GFCI
    Efficiency 92 %
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 248 x 443 x 83 mm 9.8 x 17.4 x 3.3 inch
    Weight 5.2 kg 11.5 lb
    Approvals safety: UL 458, EMC: FCC class B

    AC Master 12V 700W

    Output voltage 200/220/230/240 V – 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 100 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 700 W
    Continuous power at 40 °C / 104 °F, cos phi 1 700 W
    Peak load (1 min.) < 810 W
    Peak load (1 sec.) < 1230 W
    AC connection plug connection EU (Schuko), with UK plug (code 28210700) or with NZ/AU plug (code 28410700)
    Efficiency 91 %
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 200 x 330 x 83 mm 7.9 x 13.0 x 3.3 inch
    Weight 2.7 kg 6.0 lb
    Approvals CE, E-mark, RCM

    AC Master 12V 2500W

    Output voltage 230/240 V – 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 270 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 2500 W
    Continuous power at 40 °C / 104 °F, cos phi 1 2500 W
    Peak load (3 sec.) < 3000 W
    Peak load (< 0.2 sec.) < 4000 W
    AC connection hardwired + plug connection EU (Schuko) or with NZ/AU plug (code 28412500)
    Efficiency 88 %
    Parallel configuration yes, up to 15 units
    3-Phase configuration yes, 3 units
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 283 x 436 x 128 mm 11.1 x 17.2 x 5.0 inch
    Weight 8 kg 17.6 lb
    Approvals CE, E-mark, RCM

    AC Master 12V 1000W

    Output voltage 200/220/230/240 V – 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 130 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 1000 W
    Continuous power at 40 °C / 104 °F, cos phi 1 1000 W
    Peak load (1 min.) < 1150 W
    Peak load (1 sec.) < 1750 W
    AC connection plug connection EU (Schuko), with UK plug (code 28211000) or with NZ/AU plug (code 28411000)
    Efficiency 92 %
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 200 x 372 x 83 mm 7.9 x 14.6 x 3.3 inch
    Weight 3.3 kg 7.3 lb
    Approvals CE, E-mark, RCM

    AC Master 12V 3500W

    Output voltage 230/240 V – 50/60 Hz (selectable)
    Output waveform true sine
    Nominal battery voltage 12 V
    Recommended battery capacity ≥ 360 Ah
    Continuous power at 25 °C / 77 °F, cos phi 1 3500 W
    Continuous power at 40 °C / 104 °F, cos phi 1 3500 W
    Peak load (3 sec.) < 4500 W
    Peak load (< 0.2 sec.) < 6000 W
    AC connection hardwired + plug connection EU (Schuko), or with NZ/AU plug (code 28413500)
    Efficiency 90 %
    Parallel configuration yes, up to 15 units
    3-Phase configuration yes, 3 units
    Display/read-out LED indication: battery voltage, load level, status
    Alarms potential free alarm contact
    Dimensions, hxwxd 283 x 496 x 128 mm 11.1 x 19.5 x 5.0 inch
    Weight 10 kg 22.0 lb
    Approvals CE, E-mark, RCM